| Error | Symptom |
| 1st separation missing in LE | upgrade SW ver. from 8.1.1.i2 to 8.1.1.i4 |
| 24V short circuit | U1 I/O terminal block replace |
| 2nd transfer wizard reading at "0" | wrong Sw version on controller FP/IP |
| Air Pressure is too low | Replace air regulator |
| Air Pressure is too low | adjust air regulator minimum dial |
| Amatek always working at full speed | replaced blower |
| Atmor does not heat | Replace Atmor |
| Atmor doesn't turn on | Cable W317 in ink cabinet has switched wires |
| Auto Bias Failed | calibrate electrometer |
| Auto Bias Failed | replace electrometer board and probe |
| Auto Bias Failed | check WH leveling |
| Auto Bias Failed | Check PTE function |
| Auto Bias Failed | Calibrate Charge roller |
| Auto Bias Failed | replace PIP |
| Auto Bias Failed | Replace charge Roller |
| Auto Bias Failed | reset charge roller power |
| Auto Bias Failed | Replace whel12 |
| Auto Bias Failed | install WH parameters |
| Auto Bias Failed | replace DCI board |
| Auto Bias Failed | Check DCI cable |
| Auto Bias Failed | replace electrometer board and probe |
| Automatic Scaling fail | scalingParametersTopic > readDataFactor - set to default |
| Automatic Scaling fail | scalingParametersTopic > scanAckTimeoutInSec - set to default |
| Automatic Scaling fail | scalingParametersTopic > sensorMoveAckTimeoutInSec - set to default |
| Automatic Scaling fail | scalingParametersTopic > stepForStartPostion_A - set to default |
| Automatic Scaling fail | scalingParametersTopic > stepForMeasure_B - set to default |
| Automatic Scaling fail | scalingParametersTopic > webFedAckTimeoutInSec - set to default |
| Automatic Scaling fail | colorControlModule > repeat Length - set to default |
| Automatic Scaling fail | scalingRawDataTopic - Run the Automatic Scaling wizard,At the last stage of the wizard verify that |
| Background Yellow/Cyan/Magenta color | Rebuild Ink |
| Background Yellow/Cyan/Magenta color | Replace Bid |
| Background Yellow/Cyan/Magenta color | Color Adj+V-electrode |
| Background Yellow/Cyan/Magenta color | Full ILD |
| Background Yellow/Cyan/Magenta color | Calibrate Density+Conductivity |
| Background Yellow/Cyan/Magenta color | Replace BDU |
| Baldor status fault | replace servo start |
| Baldor status fault | perform H&T compensation wizard |
| Baldor status fault | Load servo star SW |
| Banding - Dark band at leading edge | Replace MOP |
| Banding - Dark band at leading edge | Replace Wall Engage |
| Banding - Dark band at leading edge | Rotate springs |
| Banding - Dark band at leading edge | Replace Springs |
| Banding - Dark band at leading edge | Replace FI |
| Banding - Dark band at leading edge | Replace Bid |
| Barcode not working/reading | ran barcode install from: C:>Unicorn>Install>BarcodeR>InstallBarcode.bat |
| Barcode not working/reading | Connect Barcode USB to PC |
| Barcode not working/reading | Replace Barcode reader |
| Barcode not working/reading | Teach Barcode patches |
| BCS film stuck on ITM Drum | BCS controller parameters. |
| BCS tension failed | Replace BCS belt |
| BCS tension failed | BCS roll inserted/thread wrong |
| BCS tension failed | replace BCS |
| BID 1 while testing servo motor status measured 0 | Burnt Harmonica, replace Harmonica |
| BID 2 while testing servo motor status measured 0 | Burnt Harmonica, replace Harmonica |
| BID 3 while testing servo motor status measured 0 | Burnt Harmonica, replace Harmonica |
| BID 4 while testing servo motor status measured 0 | Burnt Harmonica, replace Harmonica |
| BID 4 while testing servo motor status measured 1 | Replace BDU |
| BID 5 while testing servo motor status measured 0 | Burnt Harmonica, replace Harmonica |
| BID 6 while testing servo motor status measured 0 | Burnt Harmonica, replace Harmonica |
| Bid can't find home position | Replace BID motor |
| Bid can't find home position | Replace BID sensor |
| BID engage problem - missing image | Rotate springs |
| BID engage problem - missing image | Replace springs |
| BID engage problem - missing image | Replace Wall Engage |
| BID engage problem - missing image | Replace MOP |
| BID engage problem - missing image | Replace stepper motor |
| BID faulty | J4 connector on the BDU was switched with a J4 connector of another BDU |
| Bid HV error on NODE_0 | Replace MOP |
| BID ID not recognized | J4 connector on the BDU was switched with a J4 connector of another BDU |
| BID leak | Adjust Ink Flow |
| BID leak | Bid hose is bent |
| BID leak | FI leaks |
| BID leak | Replace BID |
| Bid motor not working | bid motor replace |
| Bid motor not working | harmonica replace |
| Bid motor not working | fuse on DCD |
| Bid motor not working | switched cables between harmonica |
| Bid motor not working | BDU replace |
| bid motor not rotating | Burt fuse on DCD |
| bid motor not rotating | No 48V on W35 cable |
| bid motor not rotating | Replace Coupling of MOP |
| BID Not in place | replace sensor (bid in place) |
| BID Not in place | Replace BID FI |
| bid not recognized | Systab parameter - mmi_config > ink replacement partly done need to be false |
| BID not recognized | J4 connector on the BDU was switched with a J4 connector of another BDU |
| bid servo motor status problem | harmonica replacement |
| bid servo motor status problem | BDU replacement |
| bid servo motor status problem | servomotor replacement |
| bid servo motor status problem | bid replacement |
| Blanket Creep | 2nd transfer & YAW adj |
| Blanket Creep | replace IMP drum |
| Blanket Creep | Replace ITM bearing |
| Blanket Creep | level the press |
| Blue Screen | perform Ghost |
| Blue Screen | reinstall Windows |
| Blue Screen | replace PC |
| C.ACC Trip | BCS controller smart card parameters reinstall |
| C.S motor not rotate | reset DCI |
| C.S motor not rotating | Replace DCI |
| C.S motor not rotating | Wiper Blade not in place |
| C.S motor not rotating | clean the IMO system |
| C.S motor not rotating | Replace IMO filter |
| C.S pump doesn't work | replace C.S pump |
| CAN BUS no communication | Replace UCN |
| CAN BUS no communication | Replace DCI |
| Cannot find WH and MCN when defining COM | Disconnect and connect the HUB USB of the PC in PE2 |
| Cannot find WH and MCN when defining COM | my computer>Manage>Devices>Ports>Update driver SW |
| Cannot upload win flash SW to controllers in 7200 | CT-net cables switched in PE1- CT-net and Jumper J5 |
| CB1 switch falls during print | Replace PS2 24v |
| CCC GUI SW doesn't come up | enable through the Systab: ContinuosColorCalibration>EnableShowGUIResult - choose TRUE in dynamic |
| Charge roller dc voltage is not like programmed | cru replaced |
| Charge roller error | Substrate was threaded wrong |
| charge roller solenoid disconnected | CRU replaced |
| charge roller solenoid disconnected | Charge Roller replace |
| charge roller solenoid disconnected | charge roller cable to CRU replace |
| Color adjustment idle for too long - Fail | restore back up parameters |
| Conductivity calibration fail | Replace TIC |
| Controller - TRIP | Replace Controller |
| Controller - TRIP ACUU.P 101 | Replace Controller |
| Controller - TRIP C.ACC | CANNOT READ FROM CONTROLLER CARD - REPLACE CARD |
| Controller - TRIP C.Cpr | load parameters to the smartcard |
| Controller - Trip C.ERR | Unidrive card is not loaded with parameters. |
| Controller - TRIP C.ERR 182 | load parameters to the smartcard |
| Controller - TRIP C.ERR 182 | Replace Smart Card |
| Controller - TRIP C.ERR 182 | Remove and place back the Smart Card |
| Controller - TRIP C.OPTN | install parameters on smart card. |
| Controller - TRIP C.OPTN | replace smart card |
| Controller - TRIP C.PROG | CONTROLLER CARD |
| Controller - Trip Encd 2 | Replace Cable |
| Controller - Trip Encd 2 | Check Encoder Cable Pins |
| Controller - Trip Encd 2 | Check Pins of Encoder connection on the Motor |
| Controller - Trip Encd 2 | Replace Motor |
| Controller - Trip Encd 2 | Switch between Encoder cables from another controller to verify problem |
| Controller - TRIP Encoder 2 | Replace Motor |
| Controller - TRIP Encoder 2 | Replace Encoder cable |
| Controller - TRIP Encoder 7 | Reset the Controller and Load new SW+parameters |
| Controller - TRIP Encoder 7 | Replace Motor |
| Controller - TRIP Encoder 7 | Replace Encoder cable |
| Controller - TRIP Encoder 7 | Data cable not connected to FE motor |
| Controller - TRIP HF xx | Replace Controller |
| Controller - TRIP HF xx | Replace Motor |
| Controller - Trip IO.AC | Replace Controller |
| Controller - Trip IO.AC | Reset the Controller and Load new SW+parameters |
| Controller - Trip IO.AC | Replace Motor |
| Controller - TRIP OI.AC UW | low output AC voltage- replace Digitax. |
| Controller - TRIP OV | check all the fuses on the controllers. |
| Controller - TRIP OV | replace damaged fuse on controller. |
| Controller - TRIP OV | check if controller FI has a "break capacitor" |
| Controller - TRIP OV | Order "Break Capacitor" |
| Controller - TRIP Ph | Check Fuse |
| Controller - TRIP SL2.HF | Pull out the SM Application and smart card and install back in |
| Controller - TRIP SL3 in the BCS Digitax | check encoder cable connection |
| Controller - TRIP SPD - Over speed | Reload Controller SW |
| Controller - TRIP T151 | Replace SM-application card |
| Controller - TRIP T152 | Install SW to Controller |
| Controller - TRIP TH | Disconnected cable on Controller |
| Controller - TRIP TX | Check Encoder cable Pins of the controller |
| Controller - TRIP TX | Check Encoder connector pins on the motor |
| Controller - TRIP TX | Switch the ENCODER cable with another controller to verify error |
| Controller - TRIP TX | Replace Encoder cable |
| Controller - TRIP TX | Replace Motor |
| Controller - TRIP TX | Replace Controller |
| Controller - TRIP UU | 24V POWER SUPPLY |
| Controller SW problem - cannot download SW (winflash) - W7200 | Wrong connection of CT-Net cable to PE and ILP |
| Controller TRIP 154 | Reload Digitax SW |
| Controller TRIP 154 | Replace SM application |
| Cooling blower failure:RPM expected 1500 actual 2000+ | Restart. Usually in First print after power up |
| Cracks | Replace blanket |
| Cracks | color adjustment calibration |
| Cracks | replace substrate |
| Cracks | 2nd transfer calibration |
| Cracks | replace ink |
| Cracks | Feed fan replace |
| Cracks | suction fan replace |
| Cracks | ITM temp calibration |
| CS motor not rotate | reset DCI |
| CT net communication error | Reload Digitax SW |
| CT net communication error | Reload PLC SW |
| CT net communication error | check on/off switches on all I/O |
| CT net communication error | check I/O address |
| CT net communication error | check Emergency Interlock line |
| Dancer on ILP not moving | Bad contact in relay K3 in the ILP |
| Density calibration fail | Replace TIC |
| Dripping fail | Replace C.S. |
| Dripping fail | Calibrate C.S flow |
| Dripping fail | Replace Sponge roller |
| Dripping fail | Hood ITM |
| Dripping fail | AMATEK replace |
| Dripping fail | Air Knife |
| DSC code 6- master encoder problem | replacing main pip encoder resolve problem(usually mcn problem) |
| EBM light doesn't turn on | connector J7 on DCI board was out |
| EBV blower not working | Replace EBV blower |
| ECN no power | TB 0.2 in PDU loose wires |
| Encoder Signal Error | Replace Encoder |
| Encoder Signal Error | Replace Main Motor |
| Encoder Signal Error | Replace Servo Star |
| Encoder signal missing | replace MCN |
| Encoder signal missing | replace Encoder |
| Encoder signal missing | check Encoder coupling |
| Encoder signal missing | check Encoder shaft |
| Encoder wizard fail | Replace PHC |
| Engine communication error -press doesn't not come up to standby | Defective job on DFE |
| EOR error | Replace Servo star |
| EOR error | Replace Main Motor |
| EOR error | Replace ITM bearings |
| EOR error | Replace PIP Brake |
| ESB no power | TB 0.2 in PDU loose wires |
| External heaters does not light | Replace PDB |
| FE Controller timeout error while downloading SW | wrong address on controller - was 192.168.101.12 instead of 192.168.101.50 under parameter 16 in the |
| FFM didn | tightened input air supply housing |
| FFM doesn't work while Printing | replace blanket |
| FFM doesn't work while Printing | remove "film" definition from substrate |
| FFM doesn't work while Printing | SW bug - Systab>host_info_only_topic>blanket_type - install and uninstall IRIS plus |
| FFM doesn't work while Printing | Close SPV |
| FP emergency error | FP guard interlock is open |
| FP emergency error | Exit door is open |
| Full Color Calibration | Rebuild Ink |
| Green page printed instead of normal job | reinstall all the ink files. |
| H+T fail | replace motor |
| H+T fail | replace servo start |
| H+T fail | check SW of servo start - (show console) |
| H+T fail | after replace motor run the press several minutes |
| Harmonica Burnt | check press temp |
| Harmonica Burnt | check chiller temp |
| Harmonica Burnt | open rear door of U.C to see if helps |
| Harmonica Burnt | replace Harmonica |
| Harmonica doesn't turn on | switched wires on J4 connector |
| Harmonica red led | Burt fuse on DCD |
| HVPS voltage error | Replace DCI |
| IBS position sensor doesn't work | Disconnected cable from PE module |
| IBS position sensor doesn't work | defective cable (green plug) |
| IBS position sensor doesn't work | defective sensor |
| ILD calibration result is too high | perform GHOST |
| ILD calibration result is too high | replace ILD |
| ILD calibration result is too high | replace BID |
| ILD calibration result is too high | Calibrate INK |
| ILD cannot find home position | clean ILD home sensor |
| ILD Density measured values are much lower then expected | download new firmware through full densitometer calibration |
| ILD initialized fail | replace ILD |
| ILD initialized fail | reload ILD |
| ILD Path too short for speed of measurement paper | adjust substrate in front and rear bounds |
| ILD- Press Timeout | install special jobs - C:unicorn-release-raid.bat SW must be down |
| ILD- Press Timeout | ILD wiring must be free so it would not hold the ILD from moving |
| ILD- Press Timeout | install ILD parameters |
| ILD- Press Timeout | erase ILD file - ILD.hex |
| ILD returned an invalid error number. Please restart the software and try again. If fails with the s | Download In-line densitometer |
| ILD/color adjustment failed - density lower than expected | calibrate ink density and conductivity |
| ILD/color adjustment failed - density lower than expected | replace ink pump |
| ILD/color adjustment failed - density lower than expected | replace ILD |
| ILD/color adjustment failed - density lower than expected | replace BID |
| ILP - there's no 230v on power supply | missing jumper on neutral block terminal |
| ILP wash cycle doesn't work | Primer & Water pump wires are switched |
| image memory | replace substrate |
| image memory | replace blanket |
| image memory | replace pip |
| image memory | 2nd transfer adj |
| image memory lost (7200) | Connection to DFE |
| Image Placement wizard missing IMAGE | set Image Placement Systab parameters to default |
| Image Placement wizard missing IMAGE | change ITM diameter |
| Image Placement wizard missing IMAGE | Wrong Paper width definition |
| Image scaling wizard failed to finish | Scaling sensor |
| Image scaling wizard failed to finish | MCU replace - scaling motor not working |
| Image scaling wizard failed to finish | MCU replace - Scaling home sensor not responding |
| Image scaling wizard failed to finish | Restore back up parameters |
| Image scaling wizard failed to finish | Replace PC |
| Image scaling wizard failed to finish | Reinstall Print Care |
| Image scaling wizard failed to finish | Systab Parameter change - Scaling>step A & Step B = 450/-450 |
| Image scaling wizard failed to finish | Restore Ghost to drive C: and S: |
| Image separation ID mismatch occurred in last separation | vcorn cable isn't at place (swapped cables) |
| Image separation lost | loose IMP drum |
| Image separation lost (7200) | Connection to DFE/ESKO |
| Image separation move | loose IMP drum |
| Image Separation change during print | Loose nut on the IMP drum - Tighten the IMP drum |
| image transfer (no image printed) | replace DCI |
| Image Transfer problem - Blank Sheet | Substrate was threaded wrong |
| Image Transfer problem - Blank Sheet | No Blanket is installed |
| Image Transfer problem - Blank Sheet | check 1st transfer parameters |
| Image Transfer problem - Blank Sheet | perform several times 1st transfer |
| Image Transfer problem - Blank Sheet | lasers are bypassed |
| IMO ink valve does not open | replace IMO valve |
| IMO ink valve does not open | Replace MIC |
| IMO ink valve does not open | Replace TIC |
| IMO pump doesn't work | replace IOC board |
| IMO pump doesn't work | replace IMO pump |
| IMP can't find home position sensor | Replace IMP motor |
| IMP can't find home position sensor | Replace IMP Home position sensor |
| IMP can't find home position sensor | check 24v in pin 27 on IP controller when sensor is at home |
| IMP can't find home position sensor | reload IP controller SW and parameters |
| IMP can't find home position sensor | Check 24v on pin 15 on J8 in the E/C & PE Module connector |
| IMP drum engages when pressing the Emergency button | air manifold of impression is switched |
| IMP engage when Emergency is pressed | air hose of impression is switched |
| Inching & Normal does not respond | Replace Servo Star |
| Inching & Normal does not respond | Replace MCN |
| Inching & Normal does not respond | Replace Main Motor |
| Inching Button on service panel doesn't work | Gray Wire of pin 6 on cable W24 (inside the service key panel) was connected to the frame (with the |
| Inching Button on service panel doesn't work | Replace service panel |
| Inching Button on service panel doesn't work | replace MCN |
| Inching mode fails and the press falls to OFF when trying to rotate the drums | Relay K4 is stuck, and it doesn't provide 24v once inching button in presses. |
| Ink Cabinet Air pressure reading is at 7.5 atm | replace MIC |
| Ink cabinet LIC pump doesn't work | replace MIC |
| INK cabinet pump doesn't work | pump Not in place |
| INK cabinet pump doesn't work | pump main rotsting shaft is loose (tight the set screw) |
| INK cabinet pump doesn't work | replace MIC |
| INK Cabinet Water Temp Sensor Is Disconnected | Cable W317 in ink cabinet has switched wires |
| INK CAN is empty error | clean INK pump |
| INK CAN is empty error | Replace INK pump |
| INK CAN is empty error | Replace Solid ad pump |
| INK could not reach desire conductivity | Drain air from Conductivity hose |
| INK could not reach desire conductivity | replace Conductivity pump |
| INK could not reach desire conductivity | Calibrate Conductivity |
| INK could not reach desire conductivity | Replace TIC |
| INK could not reach desire conductivity | Replace MIC |
| INK could not reach desire conductivity | check wiring to conductivity pump |
| INK flow calibration/error | replace ink pump |
| INK flow calibration/error | adjust ink flow |
| INK flow calibration/error | replace INK pump |
| INK flow calibration/error | calibrate Density & Conductivity |
| INK flow calibration/error | Replace BDU |
| INK flow calibration/error | Replace BID |
| ink flow fail | wall engage |
| ink flow fail | ink pump |
| ink flow fail | bid |
| ink flow fail | ????? ????? |
| ink flow fail | bid board |
| ink flow fail | BDU replace |
| ink flow fail | HVPS board |
| INK Level too low | check for leak in tank |
| INK Level too low | check leak from BID |
| INK Level too low | Replace BID |
| INK Level too low | Check return pipe from BID is not bent |
| INK Level too low | check that the INK level is not too low (can cause splash of ink and loose ink) |
| INK Level too low | calibrate Ink Flow |
| INK Level too low | IMO hose is bent |
| INK pump doesn | Replace Pump |
| INK pump doesn | Reset the MIC |
| INK pump doesn | Replace MIC |
| INK pump doesn | J4 connector on the BDU was switched with a J4 connector of another BDU |
| INK pump rotating slowly without a command | replaced MIC |
| Ink temp | input valve in ink cabinet is stuck |
| Ink temp | output valve in ink cabinet is stuck |
| Ink temp | defective water valve of tank |
| Ink temp | Replace MIC |
| Ink temp | switched main water hoses |
| INK temp is too high | Ink cabinet hoses are disconnected |
| INK temp is too high | Main water hoses are switched |
| INK temp is too high | water valve is stuck - replace valve |
| Ink transfer problem | PTE disconnected |
| Ink transfer problem | 2nd transfer |
| Ink transfer problem | first transfer |
| Ink transfer problem | Ink Replacement |
| Ink transfer problem | Bid Replacement |
| Ink transfer problem | Blanket Problem |
| Ink transfer problem | Pip Problem |
| Ink transfer problem | Check FI connections, release and install again |
| Ink White over flow | replace Bid |
| Ink White over flow | rebuild Ink |
| Ink White over flow | replace the white IMO valve |
| Ink White over flow | calibrate ink flow |
| Interlock error | Magnet missing on servis door |
| ITM External Lamp Doesn't work | Replace Dimmer |
| ITM External Lamp Doesn't work | Replace Lamp |
| ITM External Lamp Doesn't work | Check Lamp Connectors |
| ITM External Lamp Doesn't work | Relay K3 is stuck - there's no ground (-24v) to relay from PDB |
| ITM External Lamp Doesn't work | Check CAN BUS connection on DCI |
| ITM External Lamp Doesn't work | Check CAN BUS connection on PBD |
| ITM External Lamp Doesn't work | Replace PDB |
| ITM HVPS voltage failed | Cleaned the ITM heater lamp with air |
| ITM internal lamp Doesn't work | Replace Dimmer |
| ITM internal lamp Doesn't work | Check Dimmer Relay |
| ITM internal lamp Doesn't work | Check Lamp Connectors |
| ITM internal lamp works constantly | the LS1/1 Dimmer's Relay had a short circuit. |
| ITM internal lamp works constantly | LS1/1 Dimmer controller (DCB board) |
| ITM internal lamp works constantly | LS1/1 Dimmer |
| ITM internal lamp works constantly | K1 relay |
| ITM suction doesn't work | replace PDB - there's no 230VC from PDB |
| ITM temp over heat | clean ITM brushes |
| ITM temp over heat | replace ITM sensor |
| ITM temp over heat | Calibrate ITM sensor |
| ITM temperature 600.1 is out of valid range | Replace TIRS |
| ITM temperature reaching timeout | Check ITM lamps |
| K3 relay open | wrong wiring to PE IO module, no 24V. |
| Kolomorgen communication | Replace servo star |
| Kolomorgen communication | Check communication line between the Servo star and the MCN |
| Kolomorgen Interlock | check interlock line |
| Kolomorgen Interlock | Replace servo star |
| LIC pump Doesn't work | J4 connector on the BDU was switched with a J4 connector of another BDU |
| Main Drive fault | Disconnect PIP Brake and check |
| Main Drive fault | Replace PIP Brake |
| main motor doesn't stop rotating | replace K1 relay |
| Main motor high voltage | Replace Main Motor |
| Main motor high voltage | Replace Baldor/Servo Start |
| Main Motor switch (in PDU) falls when powering up the press | replace Main Motor |
| Main Motor switch (in PDU) falls when powering up the press | replace servo start |
| MCN communication | MCN replace |
| MCN communication | MCN communication port to hub malfunction |
| MCN communication | Hub replace |
| MCN communication | communication cable between MCN and Hub replace. |
| MCN communication | Replace PS4 48v power supply |
| MCN Terminal doesn't come up (empty screen) | Write again the MCN name using the CP210xset ID Software - C:>Unicorn>Release |
| MCN Terminal doesn't come up (empty screen) only 6000!!!! | in : Device manage>Ports(COM&LPT) - MCN should be without any adding's to it |
| MCN terminal doesn't respond | replace PC |
| MCN terminal doesn't respond | remove unnecessary marks of the network connection. |
| MCN terminal doesn't respond | disconnected cable from PC |
| MCN terminal doesn't respond | disconnected cable from HUB |
| MCN terminal doesn't respond | disconnected cable from WH |
| MCN terminal doesn't respond | disconnected cable from MCN |
| MCN terminal doesn't respond | replace WHEL |
| MCN terminal doesn't respond | replace MCN |
| MCN terminal doesn't respond | IP address interference |
| MCN terminal doesn't respond | hub extension cable disconnected |
| MCN terminal doesn't respond | config again the COM's |
| MCN terminal doesn't respond | Check DFE Communication |
| MCN/WHEL communication - "gibrish" | Windows Bug |
| MCN/WHEL communication - "gibrish" | perform restore GHOST |
| MIC communication error | reset MIC board |
| MIC communication error | replace MIC board |
| MIC communication error | MIC communication is loose |
| MIC fuse burnt | Check Pump Inverter |
| MIC fuse burnt | Replace Ink Pump |
| Misragistration | Replace Servo star |
| Misragistration | Perform H&T Wizard |
| Misragistration | Replace Main Motor |
| Misragistration | Encoder calibration |
| Misragistration in w6000 | DCI cable missing pin. |
| Misragistration in w6000 | Encoder calibration |
| Misragistration | change 2nd transfer pressure |
| No communication on I/O | no SW on PLC |
| No communication on I/O | wrong PLC SW |
| No communication on I/O | Profibus cable problem |
| No communication on I/O | I/O module problem |
| No communication on I/O | address problem |
| Nod bid 1 not responding | Harmonica replace |
| Nod bid 1 not responding | Replace MOP |
| Nod bid 1 not responding | BDU replace |
| Nod bid 2 not responding | Harmonica replace |
| Nod bid 2 not responding | Replace MOP |
| Nod bid 2 not responding | BDU replace |
| Nod bid 3 not responding | Harmonica replace |
| Nod bid 3 not responding | Replace MOP |
| Nod bid 3 not responding | BDU replace |
| Nod bid 4 not responding | Harmonica replace |
| Nod bid 4 not responding | Replace MOP |
| Nod bid 4 not responding | BDU replace |
| Nod bid 5 not responding | Harmonica replace |
| Nod bid 5 not responding | Replace MOP |
| Nod bid 5 not responding | BDU replace |
| Nod bid 6 not responding | Replace MOP |
| Nod bid 6 not responding | Harmonica replace |
| Nod bid 6 not responding | BDU replace |
| Node Bid 1 (bid engage wizard) | Systab parameter - Bid_Properties > Bid_Installed |
| Node Bid 6 can not recognize himself | BDU replaced |
| Node bid(x) motor0 in motion a long time | engaged bid stepper motor sensor replacement |
| NODE BID[X] While printing the current job | change in the Systab ->bidpropertiesTopic->bidinstalled->TRUE |
| Node ink[0] on can bus[4] not responding | Replace Ink Pump Inverter |
| NODE_Bid 1 (bid engage wizard) | Systab parameter - Bid_Properties > Bid_Installed |
| NODE_bid 6 can not recognize himself | bdu replaced |
| NODE_bid(x) motor 0 in motion a long time | engaged bid stepper motor sensor replacement |
| NODE_BID[X] While printing the current job | change in the Systab ->bidpropertiesTopic->bidinstalled->TRUE |
| Node_ink[0] on can bus[4] not responding | Replace Ink Pump Inverter |
| Node_ink[0] on can bus[4] not responding | mic3 replacement |
| PC doesn't see the MCN COM | Replace PC |
| PC doesn't see the MCN COM | Replace Communication cable between MCN and PC |
| PC doesn't see the MCN COM | Replace MCN |
| PC doesn't see the Whel COM | Replace Whel |
| PC doesn't see the Whel COM | Replace PC |
| PC doesn't see the Whel COM | Replace Communication cable between When and PC |
| PC doesn't shut down | perform Ghost |
| PC doesn't shut down | reinstall Windows |
| PC TOO MANY NULL CYCLES ERROR | Restore parameters (Config Save Backup) |
| PDB-dimmers communication error | pdb-dimers communication-????? j37 ? pdb |
| PDB-dimmers communication error | REPLACE DIMMER |
| PDB-dimmers communication error | REPLACE PDB |
| PEU not working | CRU replaced |
| PEU not working | SSB replace |
| PIP - loud noise at start up | Replace PIP brake |
| PIP charge below minimum limit | Electrometer probe replace |
| PIP charge below minimum limit | Electrometer probe replace |
| PIP charge below minimum limit | Electrometer Board replace |
| PIP charge below minimum limit | Adjust Leveling |
| PIP charge below minimum limit | Check PTE function |
| PIP charge below minimum limit | Check PIP in place |
| PIP charge below minimum limit | Replace CRU |
| PIP charge below minimum limit | Replace PIP foil |
| PIP charge below minimum limit | Reset Charge Roller Power |
| PIP engage noise | install PIP profile mmi_stepper |
| PIP engage noise | check voltage on stepper motor |
| PIP engage noise | check engage sensors |
| PIP engage noise | replace CRU |
| PIP engage home position error | replace PIP engage motor |
| PIP engage home position error | replace PIP engage home position sensor |
| PIP engage noise | reload PIP engage profile |
| PIP engage noise | replace PIP engage motor |
| PIP engage noise | replace CRU |
| PIP engage noise | replace PIP engage home position sensor |
| PIP engage noise | Disconnect PIP Brake and check |
| PIP engage noise | Replace PIP Brake |
| PIP overheat | Replace IMO in reservoir |
| PIP overheat | Replace IMO filter |
| PIP overheat | Replace Heat exchanger |
| PIP Rear engage motor didn't find home position | Replace motor |
| PIP Rear engage motor didn't find home position | Replace Sensor |
| PIP Rear engage motor didn't find home position | replace Gear/CAM |
| PIP Scratches | ITM IR sensor wrong calibration |
| PIP Scratches | Dirty IMO |
| PIP Scratches | Dirty Filters |
| PIP Scratches | Wiper Blade |
| PIP Scratches | Wiper Blade Housing replace |
| PIP Scratches | Clean the C.S |
| PIP Scratches | Replace the sponge roller |
| PIP Scratches | Clean the sponge roller |
| PIP Scratches | Clean the Bids |
| PIP Scratches | replace BID |
| PIP Scratches | print separate colors to see if scratches come from what BID |
| PIP Scratches | Clean the Charge Roller |
| PIP Scratches | Perform Charge roller wizard |
| PIP Scratches | Replace charge Roller |
| PIP Scratches | Look for something that touches the PIP |
| PIP Scratches | check the Air Knife position |
| PIP/ITM drum do not rotate at Inching/Normal mode | Replace MCN |
| PIP/ITM drum do not rotate at Inching/Normal mode | Replace Main Motor |
| PIP/ITM drum do not rotate at Inching/Normal mode | Replace Servo star |
| PIP/ITM drum do not rotate at Inching/Normal mode | Replace Encoder |
| PLC - no communication | PE module connection problem, disconnect and connect the PE module. |
| PLC - no communication | No 24V power coming out of U2 power supply |
| PLC - no communication | Load smart card parameters on FI controller |
| PLC - no communication | U1 I/O terminal block replace |
| PLC - no communication - BF1 and SF are red | Wrong parameters on FI controller smart card - need to program it again |
| PLC communication | I/O module problem |
| PLC communication | K3 relay open-wrong wiring to PE IO module, no 24V. |
| PLC communication | wrong address on I/O |
| PLC communication | wrong position of the ON/OFF switch on the PROFIBUS connector |
| PLC communication | Emergency interlock line is open |
| PLC communication | FI controller SW upload - WINFLASH |
| PLC communication | FI controller SM application card replace |
| PLC communication | FI controller replace |
| PLC communication | FI controller Smart card replace |
| PLC communication | FI controller Smart card SW load |
| PLC communication | PLC SW load |
| PLC communication | wrong position of the ON/OFF on RW/UW/PE module |
| Polygon banding | restore back up parameters |
| Polygon banding | replace WH+WHEL |
| Polygon banding | perform GHOST |
| Polygon over current protection | replace PLD board |
| Polygon Voltage | wire disconnected in power supply of WH |
| Press "Beeps" at standby on it's own. | Feed/Exit Door push buttons (the feeding buttons) on of them is pushed constantly. |
| Press environment temp error | check sensor |
| Press environment temp error | check chiller |
| Press environment temp error | check water hoses |
| Print is missing | wire disconnected in power supply of WH |
| Print Quality - Green page printed instead of normal job | reinstall all the ink files. |
| Printing stopped unexpectedly | Replace DFE |
| Printing stopped unexpectedly | Replace DFE SW |
| Printing stopped unexpectedly | DFE Communication |
| Printing stopped unexpectedly | Replace PC |
| Printing stopped unexpectedly | check connection of DATA Lan cable |
| Printing stopped unexpectedly | Check DFE Server |
| PS5 & PS1 power supply don't work | door interlock key is open |
| PS5 & PS1 power supply don't work | K2 relay |
| PS5 & PS1 power supply don't work | SR2 relay |
| PS5 & PS1 power supply don't work | Plug JD |
| PS5 & PS1 power supply don't work | Feed emergency |
| R.L Error message | Automatic Scaling Calibration |
| Rainbow effect | Replace charge Roller |
| Rainbow effect | Calibrate Bid Engage |
| Rainbow effect | Calibrate 1st transfer |
| Recycling Imaging Oil System Malfunctions | Dirty waste bottle |
| relay K2 not working | check 24v on pin23 on the controller (plc ready) |
| relay K2 not working | check on PLC ready on pin 33 |
| relay K2 not working | check communication of PLC |
| relay K2 not working | check addresses of all IO |
| relay K2 not working | check on/off switches on all IO |
| relay K2 not working | check SM led on PLC |
| relay K2 not working | check FI controller |
| relay K2 not working | check FI controller parameters. |
| relay K2 not working | check shutters connection in U.C. |
| Relay K3 is open | wrong wiring to PE IO module, no 24V. |
| RW cannot calibrate Roll Diameter | Load RW TSP SW |
| RW fail to run during 1st transfer & Print Cleaner | calibrate RW dancer |
| scaling in job fail | wrong SW on PLC/Controllers and servo start |
| scaling in job fail | 2nd transfer adj |
| scaling in job fail | replace blanket |
| scaling in job fail | IMP drum replace |
| scaling in job fail | IMP System replace |
| scaling in job fail | change web tension |
| scaling in job fail | change ITM diameter |
| scaling in job fail | Replace Feed |
| scaling in job fail | Replace Drive Unit |
| scaling in job fail | Replace Substrate |
| scaling in job fail | Check FP motor Coupling |
| scaling in job fail | Replace Main Motor |
| scaling in job fail | change 2nd transfer pressure from 250kg to 220kg |
| scaling problem | main motor |
| scaling problem | servo start |
| scaling problem | scaling sensor motor had a disconnected wire. |
| scaling problem 550mm | Robot installation |
| Scaling RL (between job) out of spec (breathing) | Check that the substrate doesn |
| Scaling RL (between job) out of spec (breathing) | Check all the Belt tension |
| Scaling RL (between job) out of spec (breathing) | Check substrate definition (all parameters in default except 2nd transfer pressure at 250) |
| Scaling RL (between job) out of spec (breathing) | Check rollers (clean, not loose...) |
| Scaling RL (between job) out of spec (breathing) | Check IMP engage system isn |
| Scaling RL (between job) out of spec (breathing) | Check ITM drum bearings aren |
| Scaling RL (between job) out of spec (breathing) | Replace Blanket |
| Scaling RL (between job) out of spec (breathing) | Perform 2X H+T wizard |
| Scaling RL (between job) out of spec (breathing) | Perform 2nd transfer calibration wizard |
| Scaling RL (between job) out of spec (breathing) | Check Dynamic mirror result |
| Scaling RL (between job) out of spec (breathing) | Reset Systab scaling parameters (for FP) |
| Scaling RL (between job) out of spec (breathing) | Perform scaling wizard for the FP |
| Scaling RL (between job) out of spec (breathing) | Perform auto scaling (also for second type of substrate) X2 or even 3 |
| Scaling RL (between job) out of spec (breathing) | Replace Feed Unit |
| Scaling RL (between job) out of spec (breathing) | Replace IMP kit |
| Scaling RL (between job) out of spec (breathing) | Replace FP motor |
| Scaling RL (between job) out of spec (breathing) | Replace Drive Unit |
| Scaling 1000+550 - Not in spec | Check RW Installation (????? ????????) |
| second transfer wizard reading at "0" | wrong Sw version on controller FP/IP |
| Lateral movement | 2nd transfer |
| Lateral movement | Yaw |
| Lateral movement | Substrate change |
| Lateral movement | IMP roll change |
| Lateral movement | IMP system change |
| Lateral movement | feed replace |
| Lateral movement | IBS replace |
| Lateral movement | IMP drum replace |
| Lateral movement | Drive unit replace |
| Strain Gauge REAR malfunction high result | reset to the FE Digitax and burn again |
| Strain Gauge high Value | IMP drum loose |
| Strain Gauge stuck Value | Broken connector on strain gauge |
| Strain gauge value at 0 | strain gauge wire had switched pins - defective wire - 5V did not reach the strain gauge card. |
| TIC board not communicating | reset MIC board |
| TIC board not communicating | replace MIC board |
| TIC board not communicating | replace TIC |
| TSP not uploading | TSP replace |
| TSP not uploading | UW TSP IP Address 192.168.101.13 |
| TSP not uploading | RW TSP IP Address 192.168.101.14 |
| TSP not uploading | termination inside the TSP is wrong USB/Ethernet |
| TSP not uploading | wrong SW use |
| TSP not uploading | no connection between the press PC and the TSP. |
| TSP not uploading | replace communication cable |
| UW down button | wrong wiring to EC IO module. No 24V from JMB to UW air manifold |
| UW- Hunkeler - "Battery error" | Replace Battery |
| UW- Hunkeler - "Battery error" | Replace MC3 |
| UW Hunkeler down/up button not responding | relay K2 on unit was fix/replaced |
| UW Hunkeler END of Roll | adjust photo sensor |
| UW Hunkeler END of Roll | change parameter of roll diameter on UW |
| V-corn fail during printing | Replace V-corn |
| Vcorn Failed to print | Clean the V-corn |
| W.H Missing Laser # 4 | Replaced WHEL12 |
| WH+MCN do not turn on | 24v power supply PS3 |
| Whel 12 overheating error | replace 24V power supply |
| Whel 12 overheating error | check U.C fan |
| Whel 12 overheating error | check U.C fan |
| Whel Terminal doesn't come up (empty screen) | Write again the Whel name using the CP210xset ID Software - C:>Unicorn>Release |
| Whel Terminal doesn't come up (empty screen) only 6000!!!! | in : Device manage>Ports(COM&LPT) - WHEL24 should be without any adding's to it |
| Whel terminal doesn't respond | replace PC |
| Whel terminal doesn't respond | remove unnecessary marks of the network connection. |
| Whel terminal doesn't respond | disconnected cable from PC |
| Whel terminal doesn't respond | disconnected cable from HUB |
| Whel terminal doesn't respond | disconnected cable from WH |
| Whel terminal doesn't respond | disconnected cable from MCN |
| Whel terminal doesn't respond | replace WHEL |
| Whel terminal doesn't respond | replace MCN |
| Whel terminal doesn't respond | IP address interference |
| Whel terminal doesn't respond | hub extension cable disconnected |
| Whel terminal doesn't respond | config again the COM's |
| Whel terminal doesn't respond | Check DFE Communication |
| WHS cannot run in fast mode | there's no 24v (speed limit) on pin 25 in the controllers.- check EC connector J2 and J4 |
| WHS cannot run in fast mode | Reload Controller parameters |
| WHS system does not function | Feed/Exit Door push buttons (the feeding buttons) on of them is pushed constantly. |
| Yellow missing print | bid engage wizard and manual |
| Yellow missing print | image placement |
| Yellow missing print | springs |
| Yellow missing print | bid replace |
| Yellow missing print | wall engage |
| Image Transfer lost after 1st page | check that the IMP torque bushing is locked. |
| CCC doesn't read the patches | check 0.5 bar ILD air pressure calibration. |
| Bid engage/disengage problem "jumps" | replace Cam |
| Bid engage/disengage problem "jumps" | replace Cam |
| Bid engage/disengage problem "jumps" | wrong SW version |
| Bid engage/disengage problem "jumps" | Bid engage profile |
| Misragistration | Replace Whel |
| Misragistration | Replace the WH |
| Slow DFE connection | connect the External Lan Directly from the PC to the DFE |
| Color Adjustment has a background | create new substrate definition with same parameters. |
| Color Adjustment has a background | replace Ink file |
| Color Adjustment has a background | check Conductivity and Density |
| Automatic Scaling fail -using PET substrate | change PE WHS tension to 5-6kg and change 2nd transfer presses to 200kg |
| Color adjustment idle for too long - Fail | check if ILD reaches all the way back to the home sensor |
| Color adjustment fail | check if ILD reaches all the way back to the home sensor |
| WH Automatic Line Scasing Calibration failed | Adjust the WH Camera field of view at the Systab. |
| Bid 2 motor (0) in motion too long, check sensor | Replace DCI |
| Bid 3 motor (0) in motion too long, check sensor | Replace DCI |
| Bid 4 motor (0) in motion too long, check sensor | Replace DCI |
| Cleaning station IMO flow rate wizard fail | Replace Heat exchanger |
| Cleaning station IMO flow rate wizard fail | replace IMO filters |
| Cleaning station IMO flow rate wizard fail | replace IMO in the system |
| Cleaning station IMO flow rate wizard fail | replace IMO pump |
| Cleaning station IMO flow rate wizard fail | replace Cleaning Station |
| Cleaning station IMO flow rate wizard fail | Check IMO hose from Reservoir all the way to the Cleaning Station |
| Controller TRIP 154 | Load the RW/UW Digitax SW |
| Lateral movement | check that Feed Roller driven is not loose |
| IBS position error | IBS motor coupling leaks - replace |
| IBS cannot build tension | IBS motor coupling is lose. |