1st separation missing in LEupgrade SW ver. from 8.1.1.i2 to 8.1.1.i4
24V short circuit U1 I/O terminal block replace
2nd transfer wizard reading at "0"wrong Sw version on controller FP/IP
Air Pressure is too lowReplace air regulator
Air Pressure is too lowadjust air regulator minimum dial
Amatek always working at full speedreplaced blower
Atmor does not heatReplace Atmor
Atmor doesn't turn onCable W317 in ink cabinet has switched wires
Auto Bias Failedcalibrate electrometer
Auto Bias Failedreplace electrometer board and probe
Auto Bias Failedcheck WH leveling
Auto Bias FailedCheck PTE function
Auto Bias FailedCalibrate Charge roller
Auto Bias Failedreplace PIP
Auto Bias FailedReplace charge Roller
Auto Bias Failedreset charge roller power
Auto Bias FailedReplace whel12
Auto Bias Failedinstall WH parameters
Auto Bias Failedreplace DCI board
Auto Bias FailedCheck DCI cable
Auto Bias Failedreplace electrometer board and probe
Automatic Scaling failscalingParametersTopic > readDataFactor - set to default
Automatic Scaling failscalingParametersTopic > scanAckTimeoutInSec - set to default
Automatic Scaling failscalingParametersTopic > sensorMoveAckTimeoutInSec - set to default
Automatic Scaling failscalingParametersTopic > stepForStartPostion_A - set to default
Automatic Scaling failscalingParametersTopic > stepForMeasure_B - set to default
Automatic Scaling failscalingParametersTopic > webFedAckTimeoutInSec - set to default
Automatic Scaling failcolorControlModule > repeat Length - set to default
Automatic Scaling failscalingRawDataTopic - Run the Automatic Scaling wizard,At the last stage of the wizard verify that
Background Yellow/Cyan/Magenta color Rebuild Ink
Background Yellow/Cyan/Magenta color Replace Bid
Background Yellow/Cyan/Magenta color Color Adj+V-electrode
Background Yellow/Cyan/Magenta color Full ILD
Background Yellow/Cyan/Magenta color Calibrate Density+Conductivity
Background Yellow/Cyan/Magenta color Replace BDU
Baldor status faultreplace servo start
Baldor status faultperform H&T compensation wizard
Baldor status faultLoad servo star SW
Banding - Dark band at leading edgeReplace MOP
Banding - Dark band at leading edgeReplace Wall Engage
Banding - Dark band at leading edgeRotate springs
Banding - Dark band at leading edgeReplace Springs
Banding - Dark band at leading edgeReplace FI
Banding - Dark band at leading edgeReplace Bid
Barcode not working/readingran barcode install from: C:>Unicorn>Install>BarcodeR>InstallBarcode.bat
Barcode not working/readingConnect Barcode USB to PC
Barcode not working/readingReplace Barcode reader
Barcode not working/readingTeach Barcode patches
BCS film stuck on ITM DrumBCS controller parameters.
BCS tension failedReplace BCS belt
BCS tension failedBCS roll inserted/thread wrong
BCS tension failedreplace BCS
BID 1 while testing servo motor status measured 0Burnt Harmonica, replace Harmonica
BID 2 while testing servo motor status measured 0Burnt Harmonica, replace Harmonica
BID 3 while testing servo motor status measured 0Burnt Harmonica, replace Harmonica
BID 4 while testing servo motor status measured 0Burnt Harmonica, replace Harmonica
BID 4 while testing servo motor status measured 1Replace BDU
BID 5 while testing servo motor status measured 0Burnt Harmonica, replace Harmonica
BID 6 while testing servo motor status measured 0Burnt Harmonica, replace Harmonica
Bid can't find home positionReplace BID motor
Bid can't find home positionReplace BID sensor
BID engage problem - missing imageRotate springs
BID engage problem - missing imageReplace springs
BID engage problem - missing imageReplace Wall Engage
BID engage problem - missing imageReplace MOP
BID engage problem - missing imageReplace stepper motor
BID faultyJ4 connector on the BDU was switched with a J4 connector of another BDU
Bid HV error on NODE_0Replace MOP
BID ID not recognizedJ4 connector on the BDU was switched with a J4 connector of another BDU
BID leakAdjust Ink Flow
BID leakBid hose is bent
BID leakFI leaks
BID leakReplace BID
Bid motor not workingbid motor replace
Bid motor not workingharmonica replace
Bid motor not workingfuse on DCD
Bid motor not workingswitched cables between harmonica
Bid motor not workingBDU replace
bid motor not rotatingBurt fuse on DCD
bid motor not rotatingNo 48V on W35 cable
bid motor not rotatingReplace Coupling of MOP
BID Not in placereplace sensor (bid in place)
BID Not in placeReplace BID FI
bid not recognizedSystab parameter - mmi_config > ink replacement partly done need to be false
BID not recognizedJ4 connector on the BDU was switched with a J4 connector of another BDU
bid servo motor status problemharmonica replacement
bid servo motor status problemBDU replacement
bid servo motor status problemservomotor replacement
bid servo motor status problembid replacement
Blanket Creep2nd transfer & YAW adj
Blanket Creepreplace IMP drum
Blanket CreepReplace ITM bearing
Blanket Creeplevel the press
Blue Screenperform Ghost
Blue Screenreinstall Windows
Blue Screenreplace PC
C.ACC TripBCS controller smart card parameters reinstall
C.S motor not rotatereset DCI
C.S motor not rotatingReplace DCI
C.S motor not rotatingWiper Blade not in place
C.S motor not rotatingclean the IMO system
C.S motor not rotatingReplace IMO filter
C.S pump doesn't workreplace C.S pump
CAN BUS no communication Replace UCN
CAN BUS no communication Replace DCI
Cannot find WH and MCN when defining COMDisconnect and connect the HUB USB of the PC in PE2
Cannot find WH and MCN when defining COMmy computer>Manage>Devices>Ports>Update driver SW
Cannot upload win flash SW to controllers in 7200CT-net cables switched in PE1- CT-net and Jumper J5
CB1 switch falls during printReplace PS2 24v
CCC GUI SW doesn't come upenable through the Systab: ContinuosColorCalibration>EnableShowGUIResult - choose TRUE in dynamic
Charge roller dc voltage is not like programmedcru replaced
Charge roller errorSubstrate was threaded wrong
charge roller solenoid disconnectedCRU replaced
charge roller solenoid disconnectedCharge Roller replace
charge roller solenoid disconnectedcharge roller cable to CRU replace
Color adjustment idle for too long - Failrestore back up parameters
Conductivity calibration failReplace TIC
Controller - TRIP Replace Controller
Controller - TRIP ACUU.P 101Replace Controller
Controller - TRIP C.ACCCANNOT READ FROM CONTROLLER CARD - REPLACE CARD
Controller - TRIP C.Cprload parameters to the smartcard
Controller - Trip C.ERRUnidrive card is not loaded with parameters.
Controller - TRIP C.ERR 182load parameters to the smartcard
Controller - TRIP C.ERR 182Replace Smart Card
Controller - TRIP C.ERR 182Remove and place back the Smart Card
Controller - TRIP C.OPTNinstall parameters on smart card.
Controller - TRIP C.OPTNreplace smart card
Controller - TRIP C.PROGCONTROLLER CARD
Controller - Trip Encd 2Replace Cable
Controller - Trip Encd 2Check Encoder Cable Pins
Controller - Trip Encd 2Check Pins of Encoder connection on the Motor
Controller - Trip Encd 2Replace Motor
Controller - Trip Encd 2Switch between Encoder cables from another controller to verify problem
Controller - TRIP Encoder 2Replace Motor
Controller - TRIP Encoder 2Replace Encoder cable
Controller - TRIP Encoder 7 Reset the Controller and Load new SW+parameters
Controller - TRIP Encoder 7 Replace Motor
Controller - TRIP Encoder 7 Replace Encoder cable
Controller - TRIP Encoder 7 Data cable not connected to FE motor
Controller - TRIP HF xxReplace Controller
Controller - TRIP HF xxReplace Motor
Controller - Trip IO.AC Replace Controller
Controller - Trip IO.AC Reset the Controller and Load new SW+parameters
Controller - Trip IO.AC Replace Motor
Controller - TRIP OI.AC UWlow output AC voltage- replace Digitax.
Controller - TRIP OVcheck all the fuses on the controllers.
Controller - TRIP OVreplace damaged fuse on controller.
Controller - TRIP OVcheck if controller FI has a "break capacitor"
Controller - TRIP OVOrder "Break Capacitor"
Controller - TRIP PhCheck Fuse
Controller - TRIP SL2.HFPull out the SM Application and smart card and install back in
Controller - TRIP SL3 in the BCS Digitax check encoder cable connection
Controller - TRIP SPD - Over speedReload Controller SW
Controller - TRIP T151Replace SM-application card
Controller - TRIP T152Install SW to Controller
Controller - TRIP THDisconnected cable on Controller
Controller - TRIP TXCheck Encoder cable Pins of the controller
Controller - TRIP TXCheck Encoder connector pins on the motor
Controller - TRIP TXSwitch the ENCODER cable with another controller to verify error
Controller - TRIP TXReplace Encoder cable
Controller - TRIP TXReplace Motor
Controller - TRIP TXReplace Controller
Controller - TRIP UU24V POWER SUPPLY
Controller SW problem - cannot download SW (winflash) - W7200Wrong connection of CT-Net cable to PE and ILP
Controller TRIP 154Reload Digitax SW
Controller TRIP 154Replace SM application
Cooling blower failure:RPM expected 1500 actual 2000+Restart. Usually in First print after power up
CracksReplace blanket
Crackscolor adjustment calibration
Cracksreplace substrate
Cracks2nd transfer calibration
Cracksreplace ink
CracksFeed fan replace
Crackssuction fan replace
CracksITM temp calibration
CS motor not rotatereset DCI
CT net communication errorReload Digitax SW
CT net communication errorReload PLC SW
CT net communication errorcheck on/off switches on all I/O
CT net communication errorcheck I/O address
CT net communication errorcheck Emergency Interlock line
Dancer on ILP not movingBad contact in relay K3 in the ILP
Density calibration failReplace TIC
Dripping failReplace C.S.
Dripping failCalibrate C.S flow
Dripping failReplace Sponge roller
Dripping failHood ITM
Dripping failAMATEK replace
Dripping failAir Knife
DSC code 6- master encoder problem replacing main pip encoder resolve problem(usually mcn problem)
EBM light doesn't turn onconnector J7 on DCI board was out
EBV blower not workingReplace EBV blower
ECN no powerTB 0.2 in PDU loose wires
Encoder Signal ErrorReplace Encoder
Encoder Signal ErrorReplace Main Motor
Encoder Signal ErrorReplace Servo Star
Encoder signal missingreplace MCN
Encoder signal missingreplace Encoder
Encoder signal missingcheck Encoder coupling
Encoder signal missingcheck Encoder shaft
Encoder wizard failReplace PHC
Engine communication error -press doesn't not come up to standbyDefective job on DFE
EOR errorReplace Servo star
EOR errorReplace Main Motor
EOR errorReplace ITM bearings
EOR errorReplace PIP Brake
ESB no powerTB 0.2 in PDU loose wires
External heaters does not lightReplace PDB
FE Controller timeout error while downloading SWwrong address on controller - was 192.168.101.12 instead of 192.168.101.50 under parameter 16 in the
FFM didntightened input air supply housing
FFM doesn't work while Printingreplace blanket
FFM doesn't work while Printingremove "film" definition from substrate
FFM doesn't work while PrintingSW bug - Systab>host_info_only_topic>blanket_type - install and uninstall IRIS plus
FFM doesn't work while PrintingClose SPV
FP emergency errorFP guard interlock is open
FP emergency errorExit door is open
Full Color CalibrationRebuild Ink
Green page printed instead of normal jobreinstall all the ink files.
H+T failreplace motor
H+T failreplace servo start
H+T failcheck SW of servo start - (show console)
H+T failafter replace motor run the press several minutes
Harmonica Burntcheck press temp
Harmonica Burntcheck chiller temp
Harmonica Burntopen rear door of U.C to see if helps
Harmonica Burntreplace Harmonica
Harmonica doesn't turn onswitched wires on J4 connector
Harmonica red ledBurt fuse on DCD
HVPS voltage errorReplace DCI
IBS position sensor doesn't workDisconnected cable from PE module
IBS position sensor doesn't workdefective cable (green plug)
IBS position sensor doesn't workdefective sensor
ILD calibration result is too highperform GHOST
ILD calibration result is too highreplace ILD
ILD calibration result is too highreplace BID
ILD calibration result is too highCalibrate INK
ILD cannot find home positionclean ILD home sensor
ILD Density measured values are much lower then expecteddownload new firmware through full densitometer calibration
ILD initialized failreplace ILD
ILD initialized failreload ILD
ILD Path too short for speed of measurement paperadjust substrate in front and rear bounds
ILD- Press Timeoutinstall special jobs - C:unicorn-release-raid.bat SW must be down
ILD- Press TimeoutILD wiring must be free so it would not hold the ILD from moving
ILD- Press Timeoutinstall ILD parameters
ILD- Press Timeouterase ILD file - ILD.hex
ILD returned an invalid error number. Please restart the software and try again. If fails with the sDownload In-line densitometer
ILD/color adjustment failed - density lower than expectedcalibrate ink density and conductivity
ILD/color adjustment failed - density lower than expectedreplace ink pump
ILD/color adjustment failed - density lower than expectedreplace ILD
ILD/color adjustment failed - density lower than expectedreplace BID
ILP - there's no 230v on power supplymissing jumper on neutral block terminal
ILP wash cycle doesn't workPrimer & Water pump wires are switched
image memory replace substrate
image memory replace blanket
image memory replace pip
image memory 2nd transfer adj
image memory lost (7200)Connection to DFE
Image Placement wizard missing IMAGEset Image Placement Systab parameters to default
Image Placement wizard missing IMAGEchange ITM diameter
Image Placement wizard missing IMAGEWrong Paper width definition
Image scaling wizard failed to finishScaling sensor
Image scaling wizard failed to finishMCU replace - scaling motor not working
Image scaling wizard failed to finishMCU replace - Scaling home sensor not responding
Image scaling wizard failed to finishRestore back up parameters
Image scaling wizard failed to finishReplace PC
Image scaling wizard failed to finishReinstall Print Care
Image scaling wizard failed to finishSystab Parameter change - Scaling>step A & Step B = 450/-450
Image scaling wizard failed to finishRestore Ghost to drive C: and S:
Image separation ID mismatch occurred in last separationvcorn cable isn't at place (swapped cables)
Image separation lost loose IMP drum
Image separation lost (7200)Connection to DFE/ESKO
Image separation moveloose IMP drum
Image Separation change during printLoose nut on the IMP drum - Tighten the IMP drum
image transfer (no image printed)replace DCI
Image Transfer problem - Blank SheetSubstrate was threaded wrong
Image Transfer problem - Blank SheetNo Blanket is installed
Image Transfer problem - Blank Sheetcheck 1st transfer parameters
Image Transfer problem - Blank Sheetperform several times 1st transfer
Image Transfer problem - Blank Sheetlasers are bypassed
IMO ink valve does not openreplace IMO valve
IMO ink valve does not openReplace MIC
IMO ink valve does not openReplace TIC
IMO pump doesn't workreplace IOC board
IMO pump doesn't workreplace IMO pump
IMP can't find home position sensorReplace IMP motor
IMP can't find home position sensorReplace IMP Home position sensor
IMP can't find home position sensorcheck 24v in pin 27 on IP controller when sensor is at home
IMP can't find home position sensorreload IP controller SW and parameters
IMP can't find home position sensorCheck 24v on pin 15 on J8 in the E/C & PE Module connector
IMP drum engages when pressing the Emergency buttonair manifold of impression is switched
IMP engage when Emergency is pressedair hose of impression is switched
Inching & Normal does not respondReplace Servo Star
Inching & Normal does not respondReplace MCN
Inching & Normal does not respondReplace Main Motor
Inching Button on service panel doesn't workGray Wire of pin 6 on cable W24 (inside the service key panel) was connected to the frame (with the
Inching Button on service panel doesn't workReplace service panel
Inching Button on service panel doesn't workreplace MCN
Inching mode fails and the press falls to OFF when trying to rotate the drumsRelay K4 is stuck, and it doesn't provide 24v once inching button in presses.
Ink Cabinet Air pressure reading is at 7.5 atmreplace MIC
Ink cabinet LIC pump doesn't workreplace MIC
INK cabinet pump doesn't workpump Not in place
INK cabinet pump doesn't workpump main rotsting shaft is loose (tight the set screw)
INK cabinet pump doesn't workreplace MIC
INK Cabinet Water Temp Sensor Is DisconnectedCable W317 in ink cabinet has switched wires
INK CAN is empty errorclean INK pump
INK CAN is empty errorReplace INK pump
INK CAN is empty errorReplace Solid ad pump
INK could not reach desire conductivityDrain air from Conductivity hose
INK could not reach desire conductivityreplace Conductivity pump
INK could not reach desire conductivityCalibrate Conductivity
INK could not reach desire conductivityReplace TIC
INK could not reach desire conductivityReplace MIC
INK could not reach desire conductivitycheck wiring to conductivity pump
INK flow calibration/errorreplace ink pump
INK flow calibration/erroradjust ink flow
INK flow calibration/errorreplace INK pump
INK flow calibration/errorcalibrate Density & Conductivity
INK flow calibration/errorReplace BDU
INK flow calibration/errorReplace BID
ink flow failwall engage
ink flow failink pump
ink flow failbid
ink flow fail????? ?????
ink flow failbid board
ink flow failBDU replace
ink flow failHVPS board
INK Level too lowcheck for leak in tank
INK Level too lowcheck leak from BID
INK Level too lowReplace BID
INK Level too lowCheck return pipe from BID is not bent
INK Level too lowcheck that the INK level is not too low (can cause splash of ink and loose ink)
INK Level too lowcalibrate Ink Flow
INK Level too lowIMO hose is bent
INK pump doesnReplace Pump
INK pump doesnReset the MIC
INK pump doesnReplace MIC
INK pump doesnJ4 connector on the BDU was switched with a J4 connector of another BDU
INK pump rotating slowly without a commandreplaced MIC
Ink tempinput valve in ink cabinet is stuck
Ink tempoutput valve in ink cabinet is stuck
Ink tempdefective water valve of tank
Ink tempReplace MIC
Ink tempswitched main water hoses
INK temp is too highInk cabinet hoses are disconnected
INK temp is too highMain water hoses are switched
INK temp is too highwater valve is stuck - replace valve
Ink transfer problemPTE disconnected
Ink transfer problem2nd transfer
Ink transfer problemfirst transfer
Ink transfer problemInk Replacement
Ink transfer problemBid Replacement
Ink transfer problemBlanket Problem
Ink transfer problemPip Problem
Ink transfer problemCheck FI connections, release and install again
Ink White over flowreplace Bid
Ink White over flowrebuild Ink
Ink White over flowreplace the white IMO valve
Ink White over flowcalibrate ink flow
Interlock errorMagnet missing on servis door
ITM External Lamp Doesn't workReplace Dimmer
ITM External Lamp Doesn't workReplace Lamp
ITM External Lamp Doesn't workCheck Lamp Connectors
ITM External Lamp Doesn't workRelay K3 is stuck - there's no ground (-24v) to relay from PDB
ITM External Lamp Doesn't workCheck CAN BUS connection on DCI
ITM External Lamp Doesn't workCheck CAN BUS connection on PBD
ITM External Lamp Doesn't workReplace PDB
ITM HVPS voltage failedCleaned the ITM heater lamp with air
ITM internal lamp Doesn't workReplace Dimmer
ITM internal lamp Doesn't workCheck Dimmer Relay
ITM internal lamp Doesn't workCheck Lamp Connectors
ITM internal lamp works constantlythe LS1/1 Dimmer's Relay had a short circuit.
ITM internal lamp works constantlyLS1/1 Dimmer controller (DCB board)
ITM internal lamp works constantlyLS1/1 Dimmer
ITM internal lamp works constantlyK1 relay
ITM suction doesn't workreplace PDB - there's no 230VC from PDB
ITM temp over heatclean ITM brushes
ITM temp over heatreplace ITM sensor
ITM temp over heatCalibrate ITM sensor
ITM temperature 600.1 is out of valid rangeReplace TIRS
ITM temperature reaching timeoutCheck ITM lamps
K3 relay openwrong wiring to PE IO module, no 24V.
Kolomorgen communicationReplace servo star
Kolomorgen communicationCheck communication line between the Servo star and the MCN
Kolomorgen Interlockcheck interlock line
Kolomorgen InterlockReplace servo star
LIC pump Doesn't workJ4 connector on the BDU was switched with a J4 connector of another BDU
Main Drive faultDisconnect PIP Brake and check
Main Drive faultReplace PIP Brake
main motor doesn't stop rotatingreplace K1 relay
Main motor high voltageReplace Main Motor
Main motor high voltageReplace Baldor/Servo Start
Main Motor switch (in PDU) falls when powering up the pressreplace Main Motor
Main Motor switch (in PDU) falls when powering up the pressreplace servo start
MCN communicationMCN replace
MCN communicationMCN communication port to hub malfunction
MCN communicationHub replace
MCN communicationcommunication cable between MCN and Hub replace.
MCN communicationReplace PS4 48v power supply
MCN Terminal doesn't come up (empty screen)Write again the MCN name using the CP210xset ID Software - C:>Unicorn>Release
MCN Terminal doesn't come up (empty screen) only 6000!!!!in : Device manage>Ports(COM&LPT) - MCN should be without any adding's to it
MCN terminal doesn't respondreplace PC
MCN terminal doesn't respondremove unnecessary marks of the network connection.
MCN terminal doesn't responddisconnected cable from PC
MCN terminal doesn't responddisconnected cable from HUB
MCN terminal doesn't responddisconnected cable from WH
MCN terminal doesn't responddisconnected cable from MCN
MCN terminal doesn't respondreplace WHEL
MCN terminal doesn't respondreplace MCN
MCN terminal doesn't respondIP address interference
MCN terminal doesn't respondhub extension cable disconnected
MCN terminal doesn't respondconfig again the COM's
MCN terminal doesn't respondCheck DFE Communication
MCN/WHEL communication - "gibrish"Windows Bug
MCN/WHEL communication - "gibrish"perform restore GHOST
MIC communication errorreset MIC board
MIC communication errorreplace MIC board
MIC communication errorMIC communication is loose
MIC fuse burntCheck Pump Inverter
MIC fuse burntReplace Ink Pump
MisragistrationReplace Servo star
MisragistrationPerform H&T Wizard
MisragistrationReplace Main Motor
Misragistration Encoder calibration
Misragistration in w6000DCI cable missing pin.
Misragistration in w6000Encoder calibration
Misragistrationchange 2nd transfer pressure
No communication on I/Ono SW on PLC
No communication on I/Owrong PLC SW
No communication on I/OProfibus cable problem
No communication on I/OI/O module problem
No communication on I/Oaddress problem
Nod bid 1 not respondingHarmonica replace
Nod bid 1 not respondingReplace MOP
Nod bid 1 not respondingBDU replace
Nod bid 2 not respondingHarmonica replace
Nod bid 2 not respondingReplace MOP
Nod bid 2 not respondingBDU replace
Nod bid 3 not respondingHarmonica replace
Nod bid 3 not respondingReplace MOP
Nod bid 3 not respondingBDU replace
Nod bid 4 not respondingHarmonica replace
Nod bid 4 not respondingReplace MOP
Nod bid 4 not respondingBDU replace
Nod bid 5 not respondingHarmonica replace
Nod bid 5 not respondingReplace MOP
Nod bid 5 not respondingBDU replace
Nod bid 6 not respondingReplace MOP
Nod bid 6 not respondingHarmonica replace
Nod bid 6 not respondingBDU replace
Node Bid 1 (bid engage wizard)Systab parameter - Bid_Properties > Bid_Installed
Node Bid 6 can not recognize himselfBDU replaced
Node bid(x) motor0 in motion a long timeengaged bid stepper motor sensor replacement
NODE BID[X] While printing the current jobchange in the Systab ->bidpropertiesTopic->bidinstalled->TRUE
Node ink[0] on can bus[4] not respondingReplace Ink Pump Inverter
NODE_Bid 1 (bid engage wizard)Systab parameter - Bid_Properties > Bid_Installed
NODE_bid 6 can not recognize himselfbdu replaced
NODE_bid(x) motor 0 in motion a long timeengaged bid stepper motor sensor replacement
NODE_BID[X] While printing the current jobchange in the Systab ->bidpropertiesTopic->bidinstalled->TRUE
Node_ink[0] on can bus[4] not respondingReplace Ink Pump Inverter
Node_ink[0] on can bus[4] not respondingmic3 replacement
PC doesn't see the MCN COMReplace PC
PC doesn't see the MCN COMReplace Communication cable between MCN and PC
PC doesn't see the MCN COMReplace MCN
PC doesn't see the Whel COMReplace Whel
PC doesn't see the Whel COMReplace PC
PC doesn't see the Whel COMReplace Communication cable between When and PC
PC doesn't shut down perform Ghost
PC doesn't shut down reinstall Windows
PC TOO MANY NULL CYCLES ERRORRestore parameters (Config Save Backup)
PDB-dimmers communication errorpdb-dimers communication-????? j37 ? pdb
PDB-dimmers communication errorREPLACE DIMMER
PDB-dimmers communication errorREPLACE PDB
PEU not workingCRU replaced
PEU not workingSSB replace
PIP - loud noise at start upReplace PIP brake
PIP charge below minimum limitElectrometer probe replace
PIP charge below minimum limitElectrometer probe replace
PIP charge below minimum limitElectrometer Board replace
PIP charge below minimum limitAdjust Leveling
PIP charge below minimum limitCheck PTE function
PIP charge below minimum limitCheck PIP in place
PIP charge below minimum limitReplace CRU
PIP charge below minimum limitReplace PIP foil
PIP charge below minimum limitReset Charge Roller Power
PIP engage noiseinstall PIP profile mmi_stepper
PIP engage noisecheck voltage on stepper motor
PIP engage noisecheck engage sensors
PIP engage noisereplace CRU
PIP engage home position errorreplace PIP engage motor
PIP engage home position errorreplace PIP engage home position sensor
PIP engage noisereload PIP engage profile
PIP engage noisereplace PIP engage motor
PIP engage noisereplace CRU
PIP engage noisereplace PIP engage home position sensor
PIP engage noiseDisconnect PIP Brake and check
PIP engage noiseReplace PIP Brake
PIP overheatReplace IMO in reservoir
PIP overheatReplace IMO filter
PIP overheatReplace Heat exchanger
PIP Rear engage motor didn't find home positionReplace motor
PIP Rear engage motor didn't find home positionReplace Sensor
PIP Rear engage motor didn't find home positionreplace Gear/CAM
PIP ScratchesITM IR sensor wrong calibration
PIP ScratchesDirty IMO
PIP ScratchesDirty Filters
PIP ScratchesWiper Blade
PIP ScratchesWiper Blade Housing replace
PIP ScratchesClean the C.S
PIP ScratchesReplace the sponge roller
PIP ScratchesClean the sponge roller
PIP ScratchesClean the Bids
PIP Scratchesreplace BID
PIP Scratchesprint separate colors to see if scratches come from what BID
PIP ScratchesClean the Charge Roller
PIP ScratchesPerform Charge roller wizard
PIP ScratchesReplace charge Roller
PIP ScratchesLook for something that touches the PIP
PIP Scratchescheck the Air Knife position
PIP/ITM drum do not rotate at Inching/Normal modeReplace MCN
PIP/ITM drum do not rotate at Inching/Normal modeReplace Main Motor
PIP/ITM drum do not rotate at Inching/Normal modeReplace Servo star
PIP/ITM drum do not rotate at Inching/Normal modeReplace Encoder
PLC - no communicationPE module connection problem, disconnect and connect the PE module.
PLC - no communicationNo 24V power coming out of U2 power supply
PLC - no communicationLoad smart card parameters on FI controller
PLC - no communicationU1 I/O terminal block replace
PLC - no communication - BF1 and SF are redWrong parameters on FI controller smart card - need to program it again
PLC communicationI/O module problem
PLC communicationK3 relay open-wrong wiring to PE IO module, no 24V.
PLC communicationwrong address on I/O
PLC communicationwrong position of the ON/OFF switch on the PROFIBUS connector
PLC communicationEmergency interlock line is open
PLC communicationFI controller SW upload - WINFLASH
PLC communicationFI controller SM application card replace
PLC communicationFI controller replace
PLC communicationFI controller Smart card replace
PLC communicationFI controller Smart card SW load
PLC communicationPLC SW load
PLC communicationwrong position of the ON/OFF on RW/UW/PE module
Polygon bandingrestore back up parameters
Polygon bandingreplace WH+WHEL
Polygon bandingperform GHOST
Polygon over current protectionreplace PLD board
Polygon Voltage wire disconnected in power supply of WH
Press "Beeps" at standby on it's own.Feed/Exit Door push buttons (the feeding buttons) on of them is pushed constantly.
Press environment temp errorcheck sensor
Press environment temp errorcheck chiller
Press environment temp errorcheck water hoses
Print is missing wire disconnected in power supply of WH
Print Quality - Green page printed instead of normal jobreinstall all the ink files.
Printing stopped unexpectedlyReplace DFE
Printing stopped unexpectedlyReplace DFE SW
Printing stopped unexpectedlyDFE Communication
Printing stopped unexpectedlyReplace PC
Printing stopped unexpectedlycheck connection of DATA Lan cable
Printing stopped unexpectedlyCheck DFE Server
PS5 & PS1 power supply don't workdoor interlock key is open
PS5 & PS1 power supply don't workK2 relay
PS5 & PS1 power supply don't workSR2 relay
PS5 & PS1 power supply don't workPlug JD
PS5 & PS1 power supply don't workFeed emergency
R.L Error messageAutomatic Scaling Calibration
Rainbow effectReplace charge Roller
Rainbow effectCalibrate Bid Engage
Rainbow effectCalibrate 1st transfer
Recycling Imaging Oil System MalfunctionsDirty waste bottle
relay K2 not workingcheck 24v on pin23 on the controller (plc ready)
relay K2 not workingcheck on PLC ready on pin 33
relay K2 not workingcheck communication of PLC
relay K2 not workingcheck addresses of all IO
relay K2 not workingcheck on/off switches on all IO
relay K2 not workingcheck SM led on PLC
relay K2 not workingcheck FI controller
relay K2 not workingcheck FI controller parameters.
relay K2 not workingcheck shutters connection in U.C.
Relay K3 is openwrong wiring to PE IO module, no 24V.
RW cannot calibrate Roll DiameterLoad RW TSP SW
RW fail to run during 1st transfer & Print Cleanercalibrate RW dancer
scaling in job failwrong SW on PLC/Controllers and servo start
scaling in job fail2nd transfer adj
scaling in job failreplace blanket
scaling in job failIMP drum replace
scaling in job failIMP System replace
scaling in job failchange web tension
scaling in job failchange ITM diameter
scaling in job failReplace Feed
scaling in job failReplace Drive Unit
scaling in job failReplace Substrate
scaling in job failCheck FP motor Coupling
scaling in job failReplace Main Motor
scaling in job failchange 2nd transfer pressure from 250kg to 220kg
scaling problemmain motor
scaling problemservo start
scaling problemscaling sensor motor had a disconnected wire.
scaling problem 550mm Robot installation
Scaling RL (between job) out of spec (breathing)Check that the substrate doesn
Scaling RL (between job) out of spec (breathing)Check all the Belt tension
Scaling RL (between job) out of spec (breathing)Check substrate definition (all parameters in default except 2nd transfer pressure at 250)
Scaling RL (between job) out of spec (breathing)Check rollers (clean, not loose...)
Scaling RL (between job) out of spec (breathing)Check IMP engage system isn
Scaling RL (between job) out of spec (breathing)Check ITM drum bearings aren
Scaling RL (between job) out of spec (breathing)Replace Blanket
Scaling RL (between job) out of spec (breathing)Perform 2X H+T wizard
Scaling RL (between job) out of spec (breathing)Perform 2nd transfer calibration wizard
Scaling RL (between job) out of spec (breathing)Check Dynamic mirror result
Scaling RL (between job) out of spec (breathing)Reset Systab scaling parameters (for FP)
Scaling RL (between job) out of spec (breathing)Perform scaling wizard for the FP
Scaling RL (between job) out of spec (breathing)Perform auto scaling (also for second type of substrate) X2 or even 3
Scaling RL (between job) out of spec (breathing)Replace Feed Unit
Scaling RL (between job) out of spec (breathing)Replace IMP kit
Scaling RL (between job) out of spec (breathing)Replace FP motor
Scaling RL (between job) out of spec (breathing)Replace Drive Unit
Scaling 1000+550 - Not in specCheck RW Installation (????? ????????)
second transfer wizard reading at "0"wrong Sw version on controller FP/IP
Lateral movement2nd transfer
Lateral movementYaw
Lateral movementSubstrate change
Lateral movementIMP roll change
Lateral movementIMP system change
Lateral movementfeed replace
Lateral movementIBS replace
Lateral movementIMP drum replace
Lateral movementDrive unit replace
Strain Gauge REAR malfunction high resultreset to the FE Digitax and burn again
Strain Gauge high ValueIMP drum loose
Strain Gauge stuck ValueBroken connector on strain gauge
Strain gauge value at 0strain gauge wire had switched pins - defective wire - 5V did not reach the strain gauge card.
TIC board not communicatingreset MIC board
TIC board not communicatingreplace MIC board
TIC board not communicatingreplace TIC
TSP not uploadingTSP replace
TSP not uploadingUW TSP IP Address 192.168.101.13
TSP not uploadingRW TSP IP Address 192.168.101.14
TSP not uploadingtermination inside the TSP is wrong USB/Ethernet
TSP not uploadingwrong SW use
TSP not uploadingno connection between the press PC and the TSP.
TSP not uploadingreplace communication cable
UW down buttonwrong wiring to EC IO module. No 24V from JMB to UW air manifold
UW- Hunkeler - "Battery error"Replace Battery
UW- Hunkeler - "Battery error"Replace MC3
UW Hunkeler down/up button not respondingrelay K2 on unit was fix/replaced
UW Hunkeler END of Rolladjust photo sensor
UW Hunkeler END of Rollchange parameter of roll diameter on UW
V-corn fail during printingReplace V-corn
Vcorn Failed to printClean the V-corn
W.H Missing Laser # 4 Replaced WHEL12
WH+MCN do not turn on24v power supply PS3
Whel 12 overheating errorreplace 24V power supply
Whel 12 overheating errorcheck U.C fan
Whel 12 overheating errorcheck U.C fan
Whel Terminal doesn't come up (empty screen)Write again the Whel name using the CP210xset ID Software - C:>Unicorn>Release
Whel Terminal doesn't come up (empty screen) only 6000!!!!in : Device manage>Ports(COM&LPT) - WHEL24 should be without any adding's to it
Whel terminal doesn't respondreplace PC
Whel terminal doesn't respondremove unnecessary marks of the network connection.
Whel terminal doesn't responddisconnected cable from PC
Whel terminal doesn't responddisconnected cable from HUB
Whel terminal doesn't responddisconnected cable from WH
Whel terminal doesn't responddisconnected cable from MCN
Whel terminal doesn't respondreplace WHEL
Whel terminal doesn't respondreplace MCN
Whel terminal doesn't respondIP address interference
Whel terminal doesn't respondhub extension cable disconnected
Whel terminal doesn't respondconfig again the COM's
Whel terminal doesn't respondCheck DFE Communication
WHS cannot run in fast modethere's no 24v (speed limit) on pin 25 in the controllers.- check EC connector J2 and J4
WHS cannot run in fast modeReload Controller parameters
WHS system does not functionFeed/Exit Door push buttons (the feeding buttons) on of them is pushed constantly.
Yellow missing printbid engage wizard and manual
Yellow missing printimage placement
Yellow missing printsprings
Yellow missing printbid replace
Yellow missing printwall engage
Image Transfer lost after 1st pagecheck that the IMP torque bushing is locked.
CCC doesn't read the patchescheck 0.5 bar ILD air pressure calibration.
Bid engage/disengage problem "jumps"replace Cam
Bid engage/disengage problem "jumps"replace Cam
Bid engage/disengage problem "jumps"wrong SW version
Bid engage/disengage problem "jumps"Bid engage profile
Misragistration Replace Whel
Misragistration Replace the WH
Slow DFE connectionconnect the External Lan Directly from the PC to the DFE
Color Adjustment has a backgroundcreate new substrate definition with same parameters.
Color Adjustment has a backgroundreplace Ink file
Color Adjustment has a backgroundcheck Conductivity and Density
Automatic Scaling fail -using PET substratechange PE WHS tension to 5-6kg and change 2nd transfer presses to 200kg
Color adjustment idle for too long - Failcheck if ILD reaches all the way back to the home sensor
Color adjustment failcheck if ILD reaches all the way back to the home sensor
WH Automatic Line Scasing Calibration failedAdjust the WH Camera field of view at the Systab.
Bid 2 motor (0) in motion too long, check sensorReplace DCI
Bid 3 motor (0) in motion too long, check sensorReplace DCI
Bid 4 motor (0) in motion too long, check sensorReplace DCI
Cleaning station IMO flow rate wizard failReplace Heat exchanger
Cleaning station IMO flow rate wizard failreplace IMO filters
Cleaning station IMO flow rate wizard failreplace IMO in the system
Cleaning station IMO flow rate wizard failreplace IMO pump
Cleaning station IMO flow rate wizard failreplace Cleaning Station
Cleaning station IMO flow rate wizard failCheck IMO hose from Reservoir all the way to the Cleaning Station
Controller TRIP 154Load the RW/UW Digitax SW
Lateral movementcheck that Feed Roller driven is not loose
IBS position errorIBS motor coupling leaks - replace
IBS cannot build tensionIBS motor coupling is lose.